| Strain
gauge, isolated pressure sensor |
|
|
HPR-31i-100 |
HPR-31i-200 |
HPR-31i-300 |
| Range
(psig) |
| Over
pressure (psi) |
| Burst
pressure (psi) |
|
| -15
to 100 |
-15
to 200 |
-15
to 300 |
| 300 |
600 |
600 |
| 850 |
1000 |
1000 |
|
|
| (Contact
Telog for other ranges) |
|
|
| 0.025%
of full scale, 12-bit |
|
|
| ±0.25%
of full scale at |
| constant
temperature |
|
|
| ±0.01%
of full scale per ºC |
|
|
|
|
| Programmable
from 20/sec to once every 8 hours |
|
|
| Selectable
min, max and average per interval |
|
|
| Programmable
from 1 second to every 8 hours |
|
|
| 128
Kbytes (~80,000 data values) |
|
|
|
|
| Note:
Normal mode interval data also stored during
impulse recording in separate memory. |
|
|
| Programmable
from 10/sec to once every 8 hours |
|
|
| Each
sample during triggered events + user
programmable pre & post event data
samples |
|
|
| Programmable
amplitude change during a time window (e.g. 20
PSI in 2 seconds) |
|
|
60,000
samples total divided over 450 maximum events of
variable duration.
Examples:
225 - 60 second events at 4 samples/sec
450 - 7 second events at 20 samples/sec |
|
|
| Programmable
from 20/sec up to 8 hours |
|
|
| Programmable
from 1/sec up to 8 hours |
|
|
| Selectable
min, avg & max per interval |
|
|
| 128
Kbytes (~80,000 data values( interval data
memory Plus 450 impulse events |
|